Applications:
- Structured cabling environments
- Multi-camera applications through conduit (more
cameras through a smaller diameter)
- Combining mid-span video runs into a single cable
Wire and Cable Recommendations
Twisted Sender is recommended for use with unshielded
twisted pair (UTP) wiring. The systems will operate over wire
gauges from 26 AWG through 12 AWG but are optimized for 24
AWG. Category cabling may be used.
Individually shielded
pairs should be avoided as they drastically reduce the operating
range of the systems. Multi-pair cable with an overall shield
is acceptable. Video can be operated in the same communication
cable coexistent with telephone, computer, control signals,
power voltages and other video signals. While video may be
routed through telephone punch down block terminals, any
bridge-taps, also called T-taps and any resistive, capacitive or
inductive devices MUST BE removed from the pair.
For more specific information regarding wire
types, gauges and proper installation techniques, please call
(800) 528-4343 for technical assistance.
|