Description:
The DL2105 system provides data transmission for RS232 signals at rates up to 64K Baud for distances
up to 12,000 feet (3,657 meters).
The DL2105 is designed for operation over Category 2, 3, 4 or 5 unshielded twisted pair (UTP) cables
and standard 24 AWG telephone pairs. With this system
it is unnecessary to use 18 AWG shielded pairs. The
system works equally well over existing communication
cables, computer network spare pairs or new cable installations.
A highly balanced output design assures that
the system will not interfere with other equipment on the
network.
The DL2105 units are designed for easy connection
to standard security equipment, including keyboards,
matrixes, P/T/Z systems, access control systems,
CPU units, etc.
The DL2105 is a two unit system that connects using twisted pair from transmitter to receiver to extend RS232 up to 12,000 feet (3,657 meters). All connections are via a screwless terminal block that accepts wire sizes from 14 AWG to 26 AWG. The system works with all Baud rates up to 64K. It is possible to daisy-chain up to 24 receiver units (extra receivers must be ordered separately) from a single transmitter.
The system includes a transmitter, receiver and
power supplies. Some of the typical applications include
remote keyboard control of multiplexers and matrix systems
and use in access control systems. |
Features:
- EIA RS232 standard inputs and outputs
- Data speeds of 64K baud
- Built-in surge suppression
- Balanced communication output can be run in the same cable with telephone, video and other computer signals
- Screwless terminal blocks allow easy connection to any wire type from 14 AWG to 26 AWG
|
DL2105 RS232 Extender System
The DL2105 system consists of a transmitter unit and receiver unit. The information listed below is for the system, except when noted.
| Size |
1.1"H x 2.6"W x 4.3"D (each unit, transmitter and receiver) |
| Power Requirements |
14-18 VDC @ 100mA (transmitter)
14-18 VDC @ 60mA (receiver)
(wall transformers are provided for each) |
Signal Standard |
All RS232 signals meet EIA standards |
Transmitter
Connections |
RS232 signal and ground input; Twisted pair output. Connections via screwless terminal block for 14 AWG to 26 AWG wire |
Receiver
Connections |
RS232 signal and ground output;
Twisted pair input
via screwless terminal block for
14 AWG to 26 AWG wire |
| Data Rate |
up to 64K baud |
| Surge Protection |
Built-in surge suppression is provided when earth ground connection is used |
| Temperature Range |
-40 degrees C to +85 degrees C |
| Humidity Range |
0 to 98%, non-condensing |
| Enclosure Material |
Black ABS flame retardant
plastic |
| Shipping Weight |
2 lbs |
|
|
|
| . |
| |
Applications:
- Keyboards - extends keyboards for matrix and
multiplexer control
- Access Control Systems - between buildings and
around campuses or remote gates
- Pan and Tilt Systems - extends control signals to
12,000 feet (3,657 meters) for RS232 equipment
|
|
| PART |
DESCRIPTION |
| DL1142 |
RS422 applications up to 12,000 feet (3,657 meters) |
|
Wire and Cable Recommendations
All Nitek data transmission systems are designed for use with
unshielded twisted pair (UTP) wiring. The systems will
operate over wire gauges from 24 AWG through 12 AWG.
Category 2, 3, 4 or 5 cable may be used. Tndividually shielded
pairs should be avoided, as they drastically reduce the operating
range of the systems. Multi-pair cable with an overall
shield is acceptable. The data communication signals can be
sent in the same communication cable coexistent with telephone,
computer, control signals, power voltages and video
signals (where local codes allow). While they may be routed
through telephone punch down block terminals, any bridge-taps,
also called T-taps and any resistive, capacitive or inductive
devices MUST BE removed from the pair.
For more specific
information regarding wire types, gauges and proper installation
techniques, please call 800-528-4343 for technical assistance.
|
 |
|