Document Number:
DL1142 |
Model
| DL1142 |
RS422 Line Driver for transmission up to 12,000 ft |
| |
|
| |
|
|
Revision Number:
091902 |
|
Description:
The DL1142 system provides RS422 data transmission at rates up to 64K baud for distances up to
12,000 feet (3,657 meters).
The DL1142 is designed for operation over Category
2, 3, 4 or 5 unshielded twisted pair (UTP) cables
and standard 24 AWG telephone pairs. With this system
it is unnecessary to use 18 AWG shielded pair. The unit
works equally well over existing communication cables,
computer network spares pairs or new cable installations.
A highly balanced output design assures that the system
will not interfere with other equipment on the network. The
DL1142 is designed for easy connection to standard security
equipment, including keyboards, matrixes, P/T/Z systems,
access control systems, CPU units, etc.
The DL1142 is a single unit that connects to twisted
pair wires and RS422 via a screwless terminal block for
14 AWG to 26 AWG wires. This unit can be installed at
the RS422 source or up to 4,000 feet (1,219 meters) away. The DL1142
outputs an RS422 signal that will go for an additional 12,000
feet (3,657 meters) and allows up to 32 more RS422 devices to be connected
in it.
The DL1142 works with RS422, Bi-Phase and any other RS422-type signals. Two systems will provide 4-wire
RS485 up to 12,000 feet (3,657 meters). The DL1142 can also be used to
split off or “Y” a signal allowing an RS422 run to go in two
directions. Using several units on a longer run will support
a multi-drop application of the RS422 signal.
|
Features:
- EIA standard input and output
- Data speeds of 64K baud up to 12,000 feet (3,657 meters)
- Built-in surge suppression
- Balanced communication output can be run in the
same cable with telephone, video and other computer
signals
- Screwless terminal blocks allow easy connection to
any wire type from 14 AWG to 26 AWG
|
System
| Size |
1.1"H x 2.6"W x 4.3"D |
| Power Requirements |
14-18 VDC @ 140mA (wall transformer provided with unit) |
Input |
EIA Standard RS422 |
| Output |
Amplified RS422 to meet and work
with all EIA standard equipment to
12,000 feet (3,657 meters) |
| Data Rate |
up to 64K baud |
| Surge Protection |
Built-in surge suppression is
provided when earth ground
connection is used |
| Temperature Range |
-40 degrees C to +85 degrees C |
| Humidity Range |
0 to 98%, non-condensing |
| Enclosure Material |
Black ABS Flame Retardant
Plastic |
| Shipping Weight |
1 lbs |
|
|
|
| . |
| |
Applications:
- Keyboards - extends keyboards for matrix and
multiplexer control
- Access Control Systems - between buildings and
around campuses or remote gates
- Pan and Tilt Systems - extends control signals to
12,000 feet (3,657 meters) for all major manufacturers’ equipment
|
|
| PART |
DESCRIPTION |
| DL1142 |
RS422 applications up to 12,000 feet
(3,657 meters) |
|
Wire and Cable Recommendations
All Nitek data transmission systems are designed for use with
unshielded twisted pair (UTP) wiring. The systems will
operate over wire gauges from 24 AWG through 12 AWG.
Category 2, 3, 4 or 5 cable may be used. Individually shielded
pairs should be avoided, as they drastically reduce the operating
range of the systems. Multi-pair cable with an overall
shield is acceptable. The data communication signals can be
sent in the same communication cable co-existent with telephone,
computer, control signals, power voltages and video
signals (where local codes allow). While they may be routed
through telephone punch down block terminals, any bridge-taps,
also called T-taps and any resistive, capacitive or inductive
devices MUST BE removed from the pair.
For more specific
information regarding wire types, gauges and proper installation techniques, please call 800-528-4343 for technical assistance.
|
 |
|
 |
Standard RS422 straight through hookup. The source RS422 line can be up to 4,000 feet (1,219 meters) long. The outgoing line can drive up to 32+ standard RS422 devices at up to 12,000 feet (3,657 meters) away. |
| |
 |
To split or “Y” the RS422 signals put the incoming (source) RS422 and outgoing RS422 (going to next device) wires into the same terminals. |
| |
 |
To “Y” off the RS422 signals put the incoming (source) RS422 and outgoing RS422 (going to next device) wires into the same terminals. The total length of the standard RS422 chain can be up to 4,000 feet.
This type of configuration is ideal for multi-building campus environments where a DL1142 can be located in a phone room of the building and drive RS422 devices for the entire building. |
|
|